Home • Water Treatments • Test Kit and photometers
TEST KITS AND PHOTOMETERS FOR THE ANALYSIS OF DRINKING, PROCESS AND SWIMMING POOL WATER
Cullwater offers a wide range of test kits and instruments for a complete analysis of the various chemical parameters of drinking, process and swimming pool water. Their easy use allows them to be used both by the end user and by sector operators, proving to be extremely helpful in the management and evaluation of water treatment and swimming pool systems.
Test Kit
Manual test kits for the control of single chemical water parameters with two modality of analysis: colorimetric scale or titolation
Acidity tit. | Nitrites col. 0.05-1.5 ppm |
Alkalinity M or P tit. | Nitrates col. 10-140 ppm |
Alkalinity water heater tit. | Peroxides 0.5-25 ppm (100 tests) |
Carbon dioxide tit. | pH 6.8-8.4 col. |
Ammonia col. 0.25-4 ppm | pH 1-11 universal col. |
Calcium tit. | pH - Chlorine with reagents in tablets |
Total Chlorine col. 0.1-1.5 ppm | pH - Chlorine with liquid reagents |
Free and combined Chlorine DPD 0.1-1.5 ppm | pH - Chlorine /Bromine - Alcalinity (50 tests) |
Chlorides tit. 1°F | pH - Bromine with reagents in tablets |
Hardness ECO (single component) tit. | pH - Active Oxigen with reagents in tablets |
Hardness (two-component) tit. | Cyanuric acid with reagents in tablets |
Hardness precipitation | Tester Salt NaCl (20 tests) |
Iron col. 0.05-15 ppm | Tablets DPD - Phenol Red (10 tests) |
Phosphate col. 1-20 ppm | Silica col. 0.25-8 ppm |
Phosphate col. 5-100 ppm | Sulphites tit. 2 ppm |
Manganese col. 0.05-1.5 ppm |
Tester
Pen tester for a quick analysis of the main water parameters
pH tester
Range: 0.0 a 14.0 pH
Accuracy: ± 0.1 pH
Calibration: 1 point
pH / °C waterproof tester
Two-level display
Range: -2.0 – 16.0 pH / 0.0-60.0 °C
Accuracy: ± 0.1 pH / ± 1 °C
Automatic compensation of the temperature
Calibration: automatic 1 point or 2 point (buffers)
Replaceable electrode
pH / ORP / °C waterproof tester
Two-level display
Range: -2.0 – 16.0 pH / +/- 1000 mV / -5.0 – 60.0 °C
Accuracy: ± 0.05 pH / ± 2 mV / ± 0.5 °C
Calibration: automatic 1 point or 2 point (buffers)
Replaceable electrode
Conductivity / TDS / °C waterproof tester
Two-level display
Range: 0 – 3999 µS/cm / 0 – 2000 ppm / 0.0 – 60.0 °C
Accuracy: 2% EC/TDS / ± 0.5 °C
Automatic compensation of the temperature
Replaceable electrode
Portable instruments
Portable instruments adaptable to any application
pH / ORP / °C instrument
Range: -2.0 – 20.0 pH / +/- 2000 mV / -20.0 – 120.0 °C
Resolution: 0.01 pH / 0.1 mV / 0.1 °C
Accuracy: ± 0.02 pH / ± 1 mV / ± 0.5 °C
pH / Conductivity / TDS / °C instrument
Range: -2.0 – 20.0 pH / 0 – 4000 µS/cm / 0 – 2000 ppm / -20.0 – 120.0 °C
Resolution: 0.01 pH / 1 µS/cm / 1 ppm / 0.1 °C
Accuracy: ± 0.01 pH / 2% EC/TDS / ± 0.5 °C
Conductivity / TDS / NaCl / °C instrument
Range: 0 – 2999 µS/cm / 0 – 100 g/l / 0 – 80 g/l NaCl / -20.0 – 120.0 °C
Resolution: 1 µS/cm / 1 ppm / 0.01 g/l NaCl / 0.1 °C
Accuracy: 1% EC/TDS/NaCl / ± 0.5 °C
Dissolved Oxygen (DO) / °C instrument
Range: 0 – 45 ppm O2 / -20.0 – 120.0 °C
Resolution: 0.01 ppm O2 / 0.1 °C
Accuracy: ± 1.5% O2 / ± 0.4 °C
Multiparameter photometers
Multiparameter photometeres with use of reagents
Free and Total Chlorine photometer
Range: 0.00 – 5.00 mg/l Cl2
Resolution: 0.01 mg/l
Accuracy: ± 0.06 mg/l at 1.50 mg/l
Supplied in a rigid case with reagents, two cuvettes, cleaning cloth and user manual.
pH and Free / Total Chlorine photometer
Range: 0.00 – 5.00 mg/l Cl2 / pH 6.5 – 8.0
Resolution: 0.01 mg/l Accuracy: ± 0.06 mg/l at 1.50 mg/l; ± 0,1 pH at 7.2 pH
Supplied in a rigid case with reagents, two cuvettes, cleaning cloth and user manual.
pH – Free / Total Chlorine – Cyanuric acid photometer
Range: 0.01 – 6.00 mg/l Cl2 / pH 6.5 – 8.4 / 0 – 160 mg/l Cyanuric acid
Supplied in a rigid case with reagents, cuvettes, cleaning cloth and user manual.
pH – Free / Total Chlorine – Cyanuric acid – Hardness – Alkalinity photometer
Range: 0.01 – 6.00 mg/l Cl2 / pH 6.5 – 8.4 / 0 – 160 mg/l Cyanuric acid / 0 – 500 mg/l Hardness / 5 – 200 mg/l Alcalinity
Supplied in a rigid case with reagents, cuvettes, cleaning cloth and user manual.
Turbidimeter
Range: 0.00 – 50.00 FTU and 50 – 1000 FTU
Resolution: 0.01 FTU and 1 FTU
Accuracy: ± 0.5 FTU
Supplied in a rigid case with solutions of calibration, cuvettes, cleaning cloth and user manual.
Ammonia MR photometer
Range: 0.00 – 9.99 mg/l (NH3-N)
Resolution: 0.01 mg/l
Accuracy: ± 0.30 mg/l at 5.00 mg/l
Supplied in a rigid case with reagents, two cuvettes, cleaning cloth and user manual.
Ammonia LR photometer
Range: 0.00 – 3.00 mg/l (NH3-N)
Resolution: 0.01 mg/l
Accuracy: ± 0.09 mg/l at 1.50 mg/l
Supplied in a rigid case with reagents, two cuvettes, cleaning cloth and user manual.
Iron HR photometer
Range: 0.00 – 5.00 mg/l (Fe)
Resolution: 0.01 mg/l
Accuracy: ± 0.06 mg/l at 1.50 mg/l
Supplied in a rigid case with reagents, two cuvettes, cleaning cloth and user manual.
Phosphate LR photometer
Range: 0.00 – 2.50 mg/l (PO4)
Resolution: 0.01 mg/l
Accuracy: ± 0.07 mg/l at 1.00 mg/l
Supplied in a rigid case with reagents, two cuvettes, cleaning cloth and user manual.
Chlorides photometer
Range: 0.00 – 20.00 mg/l (Cl)
Resolution: 0.01 mg/l
Accuracy: ± 1 mg/l at 10.00 mg/l